{"_buckets": {"deposit": "dda6576d-3cd7-4f68-8c7c-9fdd9b50d1dd"}, "_deposit": {"created_by": 14, "id": "8062", "owners": [14], "pid": {"revision_id": 0, "type": "depid", "value": "8062"}, "status": "published"}, "_oai": {"id": "oai:sapmed.repo.nii.ac.jp:00008062", "sets": ["1898"]}, "author_link": ["6215", "6216", "6217", "6218", "6219"], "item_2_alternative_title_18": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Cardiac Migration of Peritoneal Catheter : A Rare Complication of Ventriculo-Peritoneal Shunting"}]}, "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1993-12-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "55", "bibliographicPageStart": "52", "bibliographicVolumeNumber": "6", "bibliographic_titles": [{"bibliographic_title": "北海道脳神経疾患研究所医誌 = Journal of Hokkaido Brain Research Foundation"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A rare case of ventriculo- peritoneal shunt complication, such as a cardiac migration of the peritoneal catheter,is presented. The mechanism of the cardiac migration is thought that the peritoneal catheter might penetrate the right internal jugular vein initially and then venous flow could lead the catheter to the right atrium from the findings of the shunt revision operation.", "subitem_description_type": "Abstract"}]}, "item_2_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "URI", "subitem_identifier_uri": "http://ir.cc.sapmed.ac.jp/dspace/handle/123456789/764"}]}, "item_2_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "中村記念病院"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1340-5764", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "安斉, 公雄"}], "nameIdentifiers": [{"nameIdentifier": "6215", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中川原, 譲二"}], "nameIdentifiers": [{"nameIdentifier": "6216", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大里, 俊明"}], "nameIdentifiers": [{"nameIdentifier": "6217", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中村, 順一"}], "nameIdentifiers": [{"nameIdentifier": "6218", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "末松, 克美"}], "nameIdentifiers": [{"nameIdentifier": "6219", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-07-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "n134057646152.pdf", "filesize": [{"value": "2.7 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 2700000.0, "url": {"label": "n134057646152.pdf", "url": "https://sapmed.repo.nii.ac.jp/record/8062/files/n134057646152.pdf"}, "version_id": "1d65db00-c181-41ae-9855-866af70cf790"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "cardiac migration", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "peritoneal catheter", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "shunt functional test", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ventriculo-peritoneal shunt complication", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "脳室腹腔短絡術後、腹腔カテーテルが心臓内に迷入した1症例", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "脳室腹腔短絡術後、腹腔カテーテルが心臓内に迷入した1症例", "subitem_title_language": "ja"}]}, "item_type_id": "2", "owner": "14", "path": ["1898"], "permalink_uri": "https://sapmed.repo.nii.ac.jp/records/8062", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2009-03-24"}, "publish_date": "2009-03-24", "publish_status": "0", "recid": "8062", "relation": {}, "relation_version_is_last": true, "title": ["脳室腹腔短絡術後、腹腔カテーテルが心臓内に迷入した1症例"], "weko_shared_id": -1}
脳室腹腔短絡術後、腹腔カテーテルが心臓内に迷入した1症例
https://sapmed.repo.nii.ac.jp/records/8062
https://sapmed.repo.nii.ac.jp/records/80620e04bee7-20e1-485b-85fb-f9a98f806093
名前 / ファイル | ライセンス | アクション |
---|---|---|
n134057646152.pdf (2.7 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-03-24 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 脳室腹腔短絡術後、腹腔カテーテルが心臓内に迷入した1症例 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | cardiac migration | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | peritoneal catheter | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | shunt functional test | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | ventriculo-peritoneal shunt complication | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
安斉, 公雄
× 安斉, 公雄× 中川原, 譲二× 大里, 俊明× 中村, 順一× 末松, 克美 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A rare case of ventriculo- peritoneal shunt complication, such as a cardiac migration of the peritoneal catheter,is presented. The mechanism of the cardiac migration is thought that the peritoneal catheter might penetrate the right internal jugular vein initially and then venous flow could lead the catheter to the right atrium from the findings of the shunt revision operation. | |||||
書誌情報 |
北海道脳神経疾患研究所医誌 = Journal of Hokkaido Brain Research Foundation 巻 6, 号 1, p. 52-55, 発行日 1993-12-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1340-5764 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
その他のタイトル | ||||||
その他のタイトル | Cardiac Migration of Peritoneal Catheter : A Rare Complication of Ventriculo-Peritoneal Shunting | |||||
出版者 | ||||||
出版者 | 中村記念病院 |