WEKO3
アイテム
{"_buckets": {"deposit": "1397dcf2-5dd0-46e8-8ca3-c55def65162b"}, "_deposit": {"created_by": 14, "id": "13695", "owners": [14], "pid": {"revision_id": 0, "type": "depid", "value": "13695"}, "status": "published"}, "_oai": {"id": "oai:sapmed.repo.nii.ac.jp:00013695", "sets": ["2010"]}, "author_link": ["21329", "21330", "21331", "21332", "21333", "21334", "21335", "21336", "21337", "21338"], "item_5_alternative_title_18": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "A clinicalengineenngpointed out the early failure and an anesthesiologistoverlooked the flow sensor trouble"}]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-07-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "13", "bibliographicPageStart": "11", "bibliographicVolumeNumber": "22", "bibliographic_titles": [{"bibliographic_title": "名寄市立病院医誌 = The Jounal of Nayoro City Hospital"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "麻酔器の点検は安全な麻酔のための一つの要である。麻酔器Aespire7900は2013年秋に購入した当院では一番新しい麻酔器である。 臨床工学技士により麻酔器週間点検表に基づいた週に1 度の点検(図1) と麻酔器日常点検表にもとづいた始業前点検(図2) が行われている。さらに, 麻酔科医は麻酔科学会により推奨された始業前点検を行うよう努めている。", "subitem_description_type": "Abstract"}]}, "item_5_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "名寄市立総合病院"}]}, "item_5_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1340-2749", "subitem_source_identifier_type": "ISSN"}]}, "item_5_text_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_text_value": "http://ir.cc.sapmed.ac.jp/dspace/handle/123456789/6861"}]}, "item_5_version_type_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "舘岡, 一芳"}], "nameIdentifiers": [{"nameIdentifier": "21329", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平間, 秀昭"}], "nameIdentifiers": [{"nameIdentifier": "21330", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "和泉, 裕己"}], "nameIdentifiers": [{"nameIdentifier": "21331", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石田, 多鶴"}], "nameIdentifiers": [{"nameIdentifier": "21332", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "井尻, えり子"}], "nameIdentifiers": [{"nameIdentifier": "21333", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田浦, 伸"}], "nameIdentifiers": [{"nameIdentifier": "21334", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "関野, 貴洋"}], "nameIdentifiers": [{"nameIdentifier": "21335", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金澤, 秀和"}], "nameIdentifiers": [{"nameIdentifier": "21336", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "矢野, 真吾"}], "nameIdentifiers": [{"nameIdentifier": "21337", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大谷, 靖之"}], "nameIdentifiers": [{"nameIdentifier": "21338", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-07-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "n1340274922111.pdf", "filesize": [{"value": "6.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 6400000.0, "url": {"label": "n1340274922111.pdf", "url": "https://sapmed.repo.nii.ac.jp/record/13695/files/n1340274922111.pdf"}, "version_id": "865247c4-fb52-4f3e-be17-17b95c5e4efc"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "flow sensor", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "pre-operation inspection", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "technical report", "resourceuri": "http://purl.org/coar/resource_type/c_18gh"}]}, "item_title": "臨床工学技士により指摘された麻酔器フローセンサの初期不良と麻酔科医が見逃したフローセンサの異常", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "臨床工学技士により指摘された麻酔器フローセンサの初期不良と麻酔科医が見逃したフローセンサの異常", "subitem_title_language": "ja"}]}, "item_type_id": "5", "owner": "14", "path": ["2010"], "permalink_uri": "https://sapmed.repo.nii.ac.jp/records/13695", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2016-12-02"}, "publish_date": "2016-12-02", "publish_status": "0", "recid": "13695", "relation": {}, "relation_version_is_last": true, "title": ["臨床工学技士により指摘された麻酔器フローセンサの初期不良と麻酔科医が見逃したフローセンサの異常"], "weko_shared_id": -1}
臨床工学技士により指摘された麻酔器フローセンサの初期不良と麻酔科医が見逃したフローセンサの異常
https://sapmed.repo.nii.ac.jp/records/13695
https://sapmed.repo.nii.ac.jp/records/1369598c1394b-71e1-45ad-b6fc-43da0ea9caef
名前 / ファイル | ライセンス | アクション |
---|---|---|
n1340274922111.pdf (6.4 MB)
|
|
Item type | テクニカルレポート / Technical Report(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-12-02 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 臨床工学技士により指摘された麻酔器フローセンサの初期不良と麻酔科医が見逃したフローセンサの異常 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | flow sensor | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | pre-operation inspection | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_18gh | |||||
資源タイプ | technical report | |||||
著者 |
舘岡, 一芳
× 舘岡, 一芳× 平間, 秀昭× 和泉, 裕己× 石田, 多鶴× 井尻, えり子× 田浦, 伸× 関野, 貴洋× 金澤, 秀和× 矢野, 真吾× 大谷, 靖之 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 麻酔器の点検は安全な麻酔のための一つの要である。麻酔器Aespire7900は2013年秋に購入した当院では一番新しい麻酔器である。 臨床工学技士により麻酔器週間点検表に基づいた週に1 度の点検(図1) と麻酔器日常点検表にもとづいた始業前点検(図2) が行われている。さらに, 麻酔科医は麻酔科学会により推奨された始業前点検を行うよう努めている。 | |||||
書誌情報 |
名寄市立病院医誌 = The Jounal of Nayoro City Hospital 巻 22, 号 1, p. 11-13, 発行日 2014-07-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1340-2749 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
その他のタイトル | ||||||
その他のタイトル | A clinicalengineenngpointed out the early failure and an anesthesiologistoverlooked the flow sensor trouble | |||||
出版者 | ||||||
出版者 | 名寄市立総合病院 |