{"created":"2023-05-15T09:03:50.720023+00:00","id":8199,"links":{},"metadata":{"_buckets":{"deposit":"128782b1-9bde-4fc4-9fd5-e9d6785b65de"},"_deposit":{"created_by":15,"id":"8199","owners":[15],"pid":{"revision_id":0,"type":"depid","value":"8199"},"status":"published"},"_oai":{"id":"oai:sapmed.repo.nii.ac.jp:00008199","sets":["1674:1677:1681"]},"author_link":["6998","6999","7000","7001"],"item_2_alternative_title_18":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Simplification of Analytical Method of Ethoxyquin"}]},"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"72","bibliographicPageStart":"70","bibliographicVolumeNumber":"30","bibliographic_titles":[{"bibliographic_title":"札幌市衛生研究所年報 = Annual Report of Sapporo City Institute of Public Health"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"エトキシキンは, りんご, なしの焼け病防止剤として使用される農薬である。当所では, おもに農薬の系統分析法を用いた収去検査を行っているが, エトキシキンは系統分析法では分析できない。また, 公定法では, 回収率がかなり低い。そこで, 最新農薬の残留分析法を参考に回収率が72.2〜90.7%と良好な簡略法を開発した。","subitem_description_type":"Abstract"}]},"item_2_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"札幌市衛生研究所"}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0917-0294","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"鈴木, 恵子"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"相澤, 博"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"大谷, 倫子"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"藤田, 晃三"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-07-21"}],"displaytype":"detail","filename":"n091702943070.pdf","filesize":[{"value":"28.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"n091702943070.pdf","url":"https://sapmed.repo.nii.ac.jp/record/8199/files/n091702943070.pdf"},"version_id":"16c75d2c-af0d-442c-9a47-f3f3c2b71244"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"エトキシキン検査法の簡略化","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"エトキシキン検査法の簡略化","subitem_title_language":"ja"}]},"item_type_id":"2","owner":"15","path":["1681"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2009-03-24"},"publish_date":"2009-03-24","publish_status":"0","recid":"8199","relation_version_is_last":true,"title":["エトキシキン検査法の簡略化"],"weko_creator_id":"15","weko_shared_id":-1},"updated":"2023-12-13T04:40:42.710126+00:00"}