{"created":"2023-05-15T09:03:49.090432+00:00","id":8166,"links":{},"metadata":{"_buckets":{"deposit":"52779a75-04a1-45d9-b77b-0416f026df06"},"_deposit":{"created_by":15,"id":"8166","owners":[15],"pid":{"revision_id":0,"type":"depid","value":"8166"},"status":"published"},"_oai":{"id":"oai:sapmed.repo.nii.ac.jp:00008166","sets":["1674:1677:1678"]},"author_link":["6802","6803","6804","6805","6806","6807","6808"],"item_2_alternative_title_18":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Concentration of Aldehydes and Ketones in Room Air of a Newly Built House"}]},"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2000","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"70","bibliographicPageStart":"65","bibliographicVolumeNumber":"27","bibliographic_titles":[{"bibliographic_title":"札幌市衛生研究所年報 = Annual Report of Sapporo City Institute of Public Health"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"室内空気中のホルムアルデヒドの試料採取は2,4-DNPH捕集管を用いて行うが,この方法では他の低級アルデヒド類・ケトン類も同時に捕集される。今回,新築戸建建住宅におけるホルムアルデヒドの入居直前及び入居後10日目の濃度調査を行う機会が得られたので,この調査と併せて米国のEnviromental Protection Agency : Compendiumof Methods for the Determination of Toxic Organic Compounds in Ambient Air TO-5/TO-11に示されているアルデヒド類・ケトン類濃度についても調査を行った。この結果,ホルムアルデヒドはすべての調査試料から検出された。ジュウタンを敷いたフローリング床の居間では入居直前と入居後10日目に大きな較差が認められなかったのに対し,ジュウタンを敷かない洋間では入居後10日目には入居直前の約60%に減少していた。一方,入居直前,入居後10日目とも採取時間帯による較差は認められなかった。また,大気試料と異なり,家屋内ではその他のアルデヒド類・ケトン類として,プロピオアルデヒド,ブチルアルデヒド,ベンズアルデヒド,バレルアルデヒド,ヘキサアルデヒド等が検出された。その総量は居間,洋間とも入居後10日目には入居直前の約50%に減少していた。","subitem_description_type":"Abstract"}]},"item_2_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"札幌市衛生研究所"}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0917-0294","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"立野, 英嗣"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"恵花, 孝昭"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"山本, 優"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"浦嶋, 幸雄"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"小塚, 信一郎"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"向原, 紀彦"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"藤田, 晃三"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-07-21"}],"displaytype":"detail","filename":"n091702942765.pdf","filesize":[{"value":"307.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"n091702942765.pdf","url":"https://sapmed.repo.nii.ac.jp/record/8166/files/n091702942765.pdf"},"version_id":"4d330373-1d91-4086-9366-582440cdac9c"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"新築住宅における室内空気中のアルデヒド類・ケトン類の濃度変化について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"新築住宅における室内空気中のアルデヒド類・ケトン類の濃度変化について","subitem_title_language":"ja"}]},"item_type_id":"2","owner":"15","path":["1678"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2009-03-24"},"publish_date":"2009-03-24","publish_status":"0","recid":"8166","relation_version_is_last":true,"title":["新築住宅における室内空気中のアルデヒド類・ケトン類の濃度変化について"],"weko_creator_id":"15","weko_shared_id":-1},"updated":"2023-12-13T04:41:52.081436+00:00"}