{"created":"2023-05-15T09:03:46.009622+00:00","id":8118,"links":{},"metadata":{"_buckets":{"deposit":"b5fd4a46-bf01-4c3e-85da-c5ff57bc6c56"},"_deposit":{"created_by":14,"id":"8118","owners":[14],"pid":{"revision_id":0,"type":"depid","value":"8118"},"status":"published"},"_oai":{"id":"oai:sapmed.repo.nii.ac.jp:00008118","sets":["1875:1892:1904"]},"author_link":["6513","6514","6515","6516"],"item_2_alternative_title_18":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Dipole Analysis for Mesial Temporal Epilepsy : Comparison Between the Automatic Spike Detection System and Dr's Visual Inspection Analysis"}]},"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004-03-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"46","bibliographicPageStart":"41","bibliographicVolumeNumber":"14","bibliographic_titles":[{"bibliographic_title":"北海道脳神経疾患研究所医誌 = Journal of Hokkaido Brain Research Foundation"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Objective : To evaluate the efficacy of automatic spike detection system, we compared the dipole analysis between automatic detected spikes and visual inspection ones. Methods : A total of 10 temporal lobe epilepsy patients with hippocampal sclerosis were selected for this study. Long term video EEG monitoring were performed in all patients. Computer based automatic spike detection system checked digital EEG data, and pick up the appropriate spikes to cluster the spikes based on their morphology and topology. One representative spike group was selected for single dipole analysis. The characteristics of representative spike groups and dipole analysis results were compared between automatic defected spikes and risual inspection ones. Results : Nine out of 10 patients showed concordant spike selection between two methods. Automatic spike detection system could not detect true spikes in one patient. The topography of Case 2 demonstrated single pole electrical field over the spherical model. In Case 6, both system could detected the reliable spikes, which revealed the inconclusive dipole results due to poor signal to noise ratio. Conclusions : Automatic spike detection system could be useful for most of the mesial temporal epilepsy with hippocampal sclerosis. Because of the false negative spike detection by automatic system, visual check by experienced EEG analysts must be required for correct EEG evaluation for the mesial temporal lobe epilepsy.","subitem_description_type":"Abstract"}]},"item_2_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"中村記念病院"}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1340-5764","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"知禿, 史郎"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"溝渕, 雅広"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"鷲見, 佳泰"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"中村, 博彦"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-07-21"}],"displaytype":"detail","filename":"n1340576414141.pdf","filesize":[{"value":"2.3 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"n1340576414141.pdf","url":"https://sapmed.repo.nii.ac.jp/record/8118/files/n1340576414141.pdf"},"version_id":"66bc8335-56e9-4e8a-b448-3e408a225e4a"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"digital EEG","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"dipole analysis","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"temporal lobe epilepsy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"spike ditection","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"内側側頭葉てんかんの双極子解析;自動棘波検出法と医師による棘波選出の比較","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"内側側頭葉てんかんの双極子解析;自動棘波検出法と医師による棘波選出の比較","subitem_title_language":"ja"}]},"item_type_id":"2","owner":"14","path":["1904"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2009-03-24"},"publish_date":"2009-03-24","publish_status":"0","recid":"8118","relation_version_is_last":true,"title":["内側側頭葉てんかんの双極子解析;自動棘波検出法と医師による棘波選出の比較"],"weko_creator_id":"14","weko_shared_id":-1},"updated":"2023-12-13T03:16:31.076348+00:00"}