{"created":"2023-05-15T09:03:28.750664+00:00","id":7818,"links":{},"metadata":{"_buckets":{"deposit":"31a1ca9c-25ef-41ef-90c4-d116bb700b46"},"_deposit":{"created_by":14,"id":"7818","owners":[14],"pid":{"revision_id":0,"type":"depid","value":"7818"},"status":"published"},"_oai":{"id":"oai:sapmed.repo.nii.ac.jp:00007818","sets":["1875:1885:1889"]},"author_link":["5060","5061","5062","5063","5064"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-12-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"30","bibliographicPageStart":"28","bibliographicVolumeNumber":"31","bibliographic_titles":[{"bibliographic_title":"市立室蘭総合病院医誌 = Journal of Muroran City General Hospital"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"リングピンとケーブルワイヤーを用いて膝蓋骨骨折治療を行った5例について検討した。骨癒合は全例に認めた。臨床評価は渡邊の評価法で優3例、良2例、可0例だった。2例にケーブルワイヤーの破損を認めた。リングピンは皮膚刺激が少なく有用であるが、ケーブルワイヤーと併用する場合には、ワイヤーが破損する可能性があるため注意を要する。","subitem_description_type":"Abstract"}]},"item_2_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"市立室蘭総合病院"}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0289-2774","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"神谷, 智昭"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"石川, 一郎"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"渡邊, 吾一"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"佐藤, 貴博"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"大山, 直樹"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-07-21"}],"displaytype":"detail","filename":"n0289277431128.pdf","filesize":[{"value":"2.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"n0289277431128.pdf","url":"https://sapmed.repo.nii.ac.jp/record/7818/files/n0289277431128.pdf"},"version_id":"d9180daa-02b7-4bcf-9c60-db5d9d7315e1"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"膝蓋骨骨折","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"リングピン","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"ケーブルワイヤー","subitem_subject_language":"ja","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"リングピンとケーブルワイヤーによる膝蓋骨骨折治療の経験","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"リングピンとケーブルワイヤーによる膝蓋骨骨折治療の経験","subitem_title_language":"ja"}]},"item_type_id":"2","owner":"14","path":["1889"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2009-03-18"},"publish_date":"2009-03-18","publish_status":"0","recid":"7818","relation_version_is_last":true,"title":["リングピンとケーブルワイヤーによる膝蓋骨骨折治療の経験"],"weko_creator_id":"14","weko_shared_id":-1},"updated":"2023-12-13T03:13:17.670326+00:00"}