{"created":"2023-05-15T09:08:45.969720+00:00","id":16440,"links":{},"metadata":{"_buckets":{"deposit":"41c0a7d7-251a-4664-91d5-5cd5c536fd3d"},"_deposit":{"created_by":14,"id":"16440","owners":[14],"pid":{"revision_id":0,"type":"depid","value":"16440"},"status":"published"},"_oai":{"id":"oai:sapmed.repo.nii.ac.jp:00016440","sets":["1875:1879:2192"]},"author_link":["32430","32431","32432","32433","32434","32435","32436","32437","32438"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-09-30","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"15","bibliographicPageStart":"12","bibliographicVolumeNumber":"43","bibliographic_titles":[{"bibliographic_title":"函館医学誌 = Hakodate medical journal"},{"bibliographic_title":"Hakodate medical journal","bibliographic_titleLang":"en"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"我々は,当院で使用しているsysmex 社の多項目自動血球分析装置XN-9000に搭載されたhsA モードの基本性能を検討するにあたり,体腔液検体を対象としてBF モード・フローサイトメトリー法・目視法を用いて比較検討した。比較的良好な相関が得られたが,マクロファージや腫瘍細胞など大型の細胞が出現する一部症例については,BF モード同様相関性が低くなった。一方,低値細胞数症例においてhsA モードでのみHF 領域の細胞を検出できた症例を認めたことからBF モードと比較してより高感度に異常細胞を検出できる可能性が示唆された。","subitem_description_type":"Abstract"}]},"item_2_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"市立函館病院"}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0910-0725","subitem_source_identifier_type":"ISSN"}]},"item_2_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"作田, 泰宏"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"齋藤, 泰智"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"佐藤, 多嘉之"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"小笠原, 愛美"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"中河, 知里"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"森川, 知世"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"加藤, 有希美"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"髙屋, 絵美梨"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"秋田 隆司"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-02-25"}],"displaytype":"detail","filename":"n0910072543112.pdf","filesize":[{"value":"1.6 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"n0910072543112.pdf","url":"https://sapmed.repo.nii.ac.jp/record/16440/files/n0910072543112.pdf"},"version_id":"16351a38-0e8d-4b05-a943-65af8e774c4b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"hsA mode","subitem_subject_scheme":"Other"},{"subitem_subject":"BF mode","subitem_subject_scheme":"Other"},{"subitem_subject":"XN-9000","subitem_subject_scheme":"Other"},{"subitem_subject":"Flow cytometry","subitem_subject_scheme":"Other"},{"subitem_subject":"hsA mode","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"BF mode","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"XN-9000","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Flow cytometry","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"多項目自動血球分析装置XN-9000 を用いたhsA モードの基礎的検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"多項目自動血球分析装置XN-9000 を用いたhsA モードの基礎的検討","subitem_title_language":"ja"},{"subitem_title":"Examination of High Sensitivity Analysis mode of the Autometed Hematology Analyzer,XN-9000","subitem_title_language":"en"}]},"item_type_id":"2","owner":"14","path":["2192"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2020-02-25"},"publish_date":"2020-02-25","publish_status":"0","recid":"16440","relation_version_is_last":true,"title":["多項目自動血球分析装置XN-9000 を用いたhsA モードの基礎的検討"],"weko_creator_id":"14","weko_shared_id":-1},"updated":"2023-12-13T03:02:35.264877+00:00"}