WEKO3
アイテム
{"_buckets": {"deposit": "3a68a3c4-5870-4807-90df-b83e4b7a0b0c"}, "_deposit": {"created_by": 14, "id": "13375", "owners": [14], "pid": {"revision_id": 0, "type": "depid", "value": "13375"}, "status": "published"}, "_oai": {"id": "oai:sapmed.repo.nii.ac.jp:00013375", "sets": ["2007"]}, "author_link": ["20616", "20617", "20618", "20619", "20620", "20621", "20622", "20623", "20624"], "control_number": "13375", "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-11", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "20", "bibliographicPageStart": "16", "bibliographicVolumeNumber": "39", "bibliographic_titles": [{"bibliographic_title": "函館医学誌 = Hakodate medical journal"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "磁気共鳴診断装置(magnetic resonance imaging:MRI)は,被爆がなく低侵襲であり,高い組織コントラストにより多くの情報を得ることができる。MRI 検査は,様々な疾患に応用され,多くの診断法が確立されている。婦人科骨盤領域のMRI 検査においても,第一選択の経膣・経腹超音波に次ぐ二次検査として欠かせない補助検査となっている1,2)。現在,当院においても婦人科骨盤領域のMRI 検査では,脂肪抑制画像や造影検査を含んだルーチン検査を行っている。しかし,アレルギーなどで造影出来ない症例も経験した。造影せずに撮像可能であるT2 強調画像は,解剖学的位置関係の把握に有用とされているが比較的モーションアーチファクトが多く,診断に支障をきたす場合がある。新しいk-space 充填法であるradial scan 法は,体動補正のために開発されたk-space 充填法である。特殊なデータ収集方式により,モーションアーチファクト低減が可能である3)。婦人科骨盤領域のMRI検査では,モーションアーチファクトの原因として,呼吸による腹部の動きや腹腔内の腸管による蠕動運動がある。radial scan 法は従来法と比べ,これらのモーションアーチファクト低減により画質が向上する4-6)。このため,婦人科骨盤領域のMRI 検査では,radial scan 法が有用であるとの報告が多数されている4,5)。婦人科骨盤領域のMRI 検査において,MRI 特有のchemical shift artifact(CSA)は,脂肪の存在を示す指標であり,診断の一助とされている1,2)。しかし,近年,装置の高磁場化や新しい画像再構成技術によるk-space 充填法の登場により,従来法とは異なったCSA を生じることがある。radial scan 法では,従来法のcartesian とは異なったCSA を生ずる7)。本研究では,3.0T におけるCSA についてcartesian 法とradial scan 法を比較検討した。", "subitem_description_type": "Abstract"}]}, "item_2_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "URI", "subitem_identifier_uri": "http://ir.cc.sapmed.ac.jp/dspace/handle/123456789/6498"}]}, "item_2_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "市立函館病院"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0910-0725", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "狩野, 麻名美"}], "nameIdentifiers": [{"nameIdentifier": "20616", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "真壁, 武司"}], "nameIdentifiers": [{"nameIdentifier": "20617", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "畠山, 遼兵"}], "nameIdentifiers": [{"nameIdentifier": "20618", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐々木, 絢加"}], "nameIdentifiers": [{"nameIdentifier": "20619", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小川, 肇"}], "nameIdentifiers": [{"nameIdentifier": "20620", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安井, 太一"}], "nameIdentifiers": [{"nameIdentifier": "20621", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉川, 仁人"}], "nameIdentifiers": [{"nameIdentifier": "20622", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山下, 剛"}], "nameIdentifiers": [{"nameIdentifier": "20623", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂田, 元道"}], "nameIdentifiers": [{"nameIdentifier": "20624", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-07-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "n0910-072539116.pdf", "filesize": [{"value": "2.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 2200000.0, "url": {"label": "n0910-072539116.pdf", "url": "https://sapmed.repo.nii.ac.jp/record/13375/files/n0910-072539116.pdf"}, "version_id": "2cac1432-2c98-4f0f-b040-324b4d0be7c3"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "3.0tesla MRI", "subitem_subject_scheme": "Other"}, {"subitem_subject": "k-space trajectory", "subitem_subject_scheme": "Other"}, {"subitem_subject": "female pelvis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "chemical shift", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "3 T-MRI を使用した婦人科骨盤領域におけるk-space充填法の違いによるchemical shift artifact の比較", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "3 T-MRI を使用した婦人科骨盤領域におけるk-space充填法の違いによるchemical shift artifact の比較", "subitem_title_language": "ja"}]}, "item_type_id": "2", "owner": "14", "path": ["2007"], "permalink_uri": "https://sapmed.repo.nii.ac.jp/records/13375", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2016-01-21"}, "publish_date": "2016-01-21", "publish_status": "0", "recid": "13375", "relation": {}, "relation_version_is_last": true, "title": ["3 T-MRI を使用した婦人科骨盤領域におけるk-space充填法の違いによるchemical shift artifact の比較"], "weko_shared_id": -1}
3 T-MRI を使用した婦人科骨盤領域におけるk-space充填法の違いによるchemical shift artifact の比較
https://sapmed.repo.nii.ac.jp/records/13375
https://sapmed.repo.nii.ac.jp/records/13375a8cb9bd2-5620-4461-9826-3b0c89fd5fee
名前 / ファイル | ライセンス | アクション |
---|---|---|
n0910-072539116.pdf (2.2 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-01-21 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 3 T-MRI を使用した婦人科骨盤領域におけるk-space充填法の違いによるchemical shift artifact の比較 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 3.0tesla MRI | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | k-space trajectory | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | female pelvis | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | chemical shift | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
狩野, 麻名美
× 狩野, 麻名美× 真壁, 武司× 畠山, 遼兵× 佐々木, 絢加× 小川, 肇× 安井, 太一× 吉川, 仁人× 山下, 剛× 坂田, 元道 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 磁気共鳴診断装置(magnetic resonance imaging:MRI)は,被爆がなく低侵襲であり,高い組織コントラストにより多くの情報を得ることができる。MRI 検査は,様々な疾患に応用され,多くの診断法が確立されている。婦人科骨盤領域のMRI 検査においても,第一選択の経膣・経腹超音波に次ぐ二次検査として欠かせない補助検査となっている1,2)。現在,当院においても婦人科骨盤領域のMRI 検査では,脂肪抑制画像や造影検査を含んだルーチン検査を行っている。しかし,アレルギーなどで造影出来ない症例も経験した。造影せずに撮像可能であるT2 強調画像は,解剖学的位置関係の把握に有用とされているが比較的モーションアーチファクトが多く,診断に支障をきたす場合がある。新しいk-space 充填法であるradial scan 法は,体動補正のために開発されたk-space 充填法である。特殊なデータ収集方式により,モーションアーチファクト低減が可能である3)。婦人科骨盤領域のMRI検査では,モーションアーチファクトの原因として,呼吸による腹部の動きや腹腔内の腸管による蠕動運動がある。radial scan 法は従来法と比べ,これらのモーションアーチファクト低減により画質が向上する4-6)。このため,婦人科骨盤領域のMRI 検査では,radial scan 法が有用であるとの報告が多数されている4,5)。婦人科骨盤領域のMRI 検査において,MRI 特有のchemical shift artifact(CSA)は,脂肪の存在を示す指標であり,診断の一助とされている1,2)。しかし,近年,装置の高磁場化や新しい画像再構成技術によるk-space 充填法の登場により,従来法とは異なったCSA を生じることがある。radial scan 法では,従来法のcartesian とは異なったCSA を生ずる7)。本研究では,3.0T におけるCSA についてcartesian 法とradial scan 法を比較検討した。 | |||||
書誌情報 |
函館医学誌 = Hakodate medical journal 巻 39, 号 1, p. 16-20, 発行日 2015-11 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0910-0725 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | 市立函館病院 |