WEKO3
アイテム
{"_buckets": {"deposit": "eb4a1fdd-6f59-4ece-bce8-32c9a1f7f2ab"}, "_deposit": {"created_by": 15, "id": "10569", "owners": [15], "pid": {"revision_id": 0, "type": "depid", "value": "10569"}, "status": "published"}, "_oai": {"id": "oai:sapmed.repo.nii.ac.jp:00010569", "sets": ["1750"]}, "author_link": ["13857", "13858", "13859", "13860", "13861", "13862", "13863", "13864", "13865"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-03-31", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "67", "bibliographicPageStart": "64", "bibliographicVolumeNumber": "25", "bibliographic_titles": [{"bibliographic_title": "北海道整形外科外傷研究会会誌 = The Journal of Hokkaido Orthopaedic Traumatology Association"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "橈骨遠位端骨折に対する掌側ロッキングプレート固定後に生じたプレート折損の3例を報告した.3例ともAO23?C2症例で骨幹端部の粉砕を伴っていた.外固定期間はそれぞれ,なし。3週,4日であったが,3週行った症例も対側の上腕骨骨折があり,患肢が支持肢となっていた可能性があった.他の2例も術後早期より現職に復帰し患肢をよく使用していた.人工骨移植を2例に行ったが充分な支持性が得られなかった.骨粗鬆症,骨幹端の粉砕が著しい症例では,掌側ロッキングプレートの固定性を過信せず,決して万能なインプラントでないことを肝に銘じておく必要がある.", "subitem_description_type": "Abstract"}]}, "item_2_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "URI", "subitem_identifier_uri": "http://ir.cc.sapmed.ac.jp/dspace/handle/123456789/3543"}]}, "item_2_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "北海道整形外科外傷研究会"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0914-6083", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "新井, 学"}], "nameIdentifiers": [{"nameIdentifier": "13857", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "辻, 英樹"}], "nameIdentifiers": [{"nameIdentifier": "13858", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "磯貝, 哲"}], "nameIdentifiers": [{"nameIdentifier": "13859", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "倉田, 佳明"}], "nameIdentifiers": [{"nameIdentifier": "13860", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐々木, 友基"}], "nameIdentifiers": [{"nameIdentifier": "13861", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田邊, 康"}], "nameIdentifiers": [{"nameIdentifier": "13862", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森, 利光"}], "nameIdentifiers": [{"nameIdentifier": "13863", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "土田, 芳彦"}], "nameIdentifiers": [{"nameIdentifier": "13864", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村上, 裕子"}], "nameIdentifiers": [{"nameIdentifier": "13865", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-07-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "n091460832564.pdf", "filesize": [{"value": "347.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 347900.0, "url": {"label": "n091460832564.pdf", "url": "https://sapmed.repo.nii.ac.jp/record/10569/files/n091460832564.pdf"}, "version_id": "01f29c85-011a-4e4a-883e-78677d235590"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Distal radius fracture", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Volar locking plate", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Plate breakage", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "橈骨遠位端骨折", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "掌側ロッキングプレート", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "プレート折損", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "橈骨遠位端骨折掌側ロッキングプレート固定後プレート折損の3例", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "橈骨遠位端骨折掌側ロッキングプレート固定後プレート折損の3例", "subitem_title_language": "ja"}]}, "item_type_id": "2", "owner": "15", "path": ["1750"], "permalink_uri": "https://sapmed.repo.nii.ac.jp/records/10569", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2009-09-09"}, "publish_date": "2009-09-09", "publish_status": "0", "recid": "10569", "relation": {}, "relation_version_is_last": true, "title": ["橈骨遠位端骨折掌側ロッキングプレート固定後プレート折損の3例"], "weko_shared_id": -1}
橈骨遠位端骨折掌側ロッキングプレート固定後プレート折損の3例
https://sapmed.repo.nii.ac.jp/records/10569
https://sapmed.repo.nii.ac.jp/records/1056975f6c984-3037-4d7f-bb83-d081aebfadcb
名前 / ファイル | ライセンス | アクション |
---|---|---|
n091460832564.pdf (347.9 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-09-09 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 橈骨遠位端骨折掌側ロッキングプレート固定後プレート折損の3例 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Distal radius fracture | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Volar locking plate | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Plate breakage | |||||
キーワード | ||||||
言語 | ja | |||||
主題Scheme | Other | |||||
主題 | 橈骨遠位端骨折 | |||||
キーワード | ||||||
言語 | ja | |||||
主題Scheme | Other | |||||
主題 | 掌側ロッキングプレート | |||||
キーワード | ||||||
言語 | ja | |||||
主題Scheme | Other | |||||
主題 | プレート折損 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
新井, 学
× 新井, 学× 辻, 英樹× 磯貝, 哲× 倉田, 佳明× 佐々木, 友基× 田邊, 康× 森, 利光× 土田, 芳彦× 村上, 裕子 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 橈骨遠位端骨折に対する掌側ロッキングプレート固定後に生じたプレート折損の3例を報告した.3例ともAO23?C2症例で骨幹端部の粉砕を伴っていた.外固定期間はそれぞれ,なし。3週,4日であったが,3週行った症例も対側の上腕骨骨折があり,患肢が支持肢となっていた可能性があった.他の2例も術後早期より現職に復帰し患肢をよく使用していた.人工骨移植を2例に行ったが充分な支持性が得られなかった.骨粗鬆症,骨幹端の粉砕が著しい症例では,掌側ロッキングプレートの固定性を過信せず,決して万能なインプラントでないことを肝に銘じておく必要がある. | |||||
書誌情報 |
北海道整形外科外傷研究会会誌 = The Journal of Hokkaido Orthopaedic Traumatology Association 巻 25, p. 64-67, 発行日 2009-03-31 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0914-6083 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | 北海道整形外科外傷研究会 |