{"_buckets": {"deposit": "9b353b76-c1a4-4ee5-a8c5-48d4b318b70e"}, "_deposit": {"created_by": 15, "id": "10555", "owners": [15], "pid": {"revision_id": 0, "type": "depid", "value": "10555"}, "status": "published"}, "_oai": {"id": "oai:sapmed.repo.nii.ac.jp:00010555", "sets": ["1750"]}, "author_link": ["13808", "13809", "13810", "13811", "13812"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-03-31", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "22", "bibliographicPageStart": "18", "bibliographicVolumeNumber": "25", "bibliographic_titles": [{"bibliographic_title": "北海道整形外科外傷研究会会誌 = The Journal of Hokkaido Orthopaedic Traumatology Association"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "近年,橈骨遠位端骨折に対する掌側ロッキングプレートの有用性が報告されている.当院でも2007年4月より,不安定型橈骨遠位端骨折に対して,Stryker 社;Matrix Smart Lock Polyaxial Locking System(以下Matrix)を使用してきた.今回,2007年4月から,2008年3月までMatrixを用いて手術した,30例30手について,術後X 線学的検討を行った.術直後と最終診察時のvolar tilt(以下VT),radial tilt(以下RT),ulnar variance(以下UV)を計測したところ,概ね保たれていた.しかし,術後1?3週の間に,6例でlocking screw のloosening を認め,それらのVT とUVの保持は困難であった.Marrix は,任意の方向に10°の角度をつけて挿入することができるため,さまざまな骨折型に対応できる.しかし,ロッキング機構が働いたかどうかを確認することが難しいと考えられた.", "subitem_description_type": "Abstract"}]}, "item_2_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "URI", "subitem_identifier_uri": "http://ir.cc.sapmed.ac.jp/dspace/handle/123456789/3529"}]}, "item_2_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "北海道整形外科外傷研究会"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0914-6083", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "工藤, 道子"}], "nameIdentifiers": [{"nameIdentifier": "13808", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "辻, 英樹"}], "nameIdentifiers": [{"nameIdentifier": "13809", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森, 利光"}], "nameIdentifiers": [{"nameIdentifier": "13810", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "土田, 芳彦"}], "nameIdentifiers": [{"nameIdentifier": "13811", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "磯貝, 哲"}], "nameIdentifiers": [{"nameIdentifier": "13812", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-07-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "n091460832518.pdf", "filesize": [{"value": "309.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 309800.0, "url": {"label": "n091460832518.pdf", "url": "https://sapmed.repo.nii.ac.jp/record/10555/files/n091460832518.pdf"}, "version_id": "92519599-a326-4bac-a794-5ce73dc14e33"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Distal radius fracture", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Palmar locking plate", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "橈骨遠位端骨折", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "掌側ロッキングプレート", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "橈骨遠位端骨折に対する掌側ロッキングプレート固定のX 線検討", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "橈骨遠位端骨折に対する掌側ロッキングプレート固定のX 線検討", "subitem_title_language": "ja"}]}, "item_type_id": "2", "owner": "15", "path": ["1750"], "permalink_uri": "https://sapmed.repo.nii.ac.jp/records/10555", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2009-09-09"}, "publish_date": "2009-09-09", "publish_status": "0", "recid": "10555", "relation": {}, "relation_version_is_last": true, "title": ["橈骨遠位端骨折に対する掌側ロッキングプレート固定のX 線検討"], "weko_shared_id": -1}
橈骨遠位端骨折に対する掌側ロッキングプレート固定のX 線検討
https://sapmed.repo.nii.ac.jp/records/10555
https://sapmed.repo.nii.ac.jp/records/10555fc2c4e1f-b888-46a8-b8b3-d1cf98b2763a
名前 / ファイル | ライセンス | アクション |
---|---|---|
n091460832518.pdf (309.8 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-09-09 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 橈骨遠位端骨折に対する掌側ロッキングプレート固定のX 線検討 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Distal radius fracture | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Palmar locking plate | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | 橈骨遠位端骨折 | |||||
キーワード | ||||||
言語 | ja | |||||
主題Scheme | Other | |||||
主題 | 掌側ロッキングプレート | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
工藤, 道子
× 工藤, 道子× 辻, 英樹× 森, 利光× 土田, 芳彦× 磯貝, 哲 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 近年,橈骨遠位端骨折に対する掌側ロッキングプレートの有用性が報告されている.当院でも2007年4月より,不安定型橈骨遠位端骨折に対して,Stryker 社;Matrix Smart Lock Polyaxial Locking System(以下Matrix)を使用してきた.今回,2007年4月から,2008年3月までMatrixを用いて手術した,30例30手について,術後X 線学的検討を行った.術直後と最終診察時のvolar tilt(以下VT),radial tilt(以下RT),ulnar variance(以下UV)を計測したところ,概ね保たれていた.しかし,術後1?3週の間に,6例でlocking screw のloosening を認め,それらのVT とUVの保持は困難であった.Marrix は,任意の方向に10°の角度をつけて挿入することができるため,さまざまな骨折型に対応できる.しかし,ロッキング機構が働いたかどうかを確認することが難しいと考えられた. | |||||
書誌情報 |
北海道整形外科外傷研究会会誌 = The Journal of Hokkaido Orthopaedic Traumatology Association 巻 25, p. 18-22, 発行日 2009-03-31 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0914-6083 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | 北海道整形外科外傷研究会 |