{"_buckets": {"deposit": "e92ecd38-04d0-48a3-a0d2-e07ea0af958f"}, "_deposit": {"created_by": 15, "id": "10513", "owners": [15], "pid": {"revision_id": 0, "type": "depid", "value": "10513"}, "status": "published"}, "_oai": {"id": "oai:sapmed.repo.nii.ac.jp:00010513", "sets": ["1749"]}, "author_link": ["13725"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-03-31", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "12", "bibliographicPageStart": "10", "bibliographicVolumeNumber": "24", "bibliographic_titles": [{"bibliographic_title": "北海道整形外科外傷研究会会誌 = The Journal of Hokkaido Orthopaedic Traumatology Association"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Non-bridge 型創外固定(Techno FIX)は全長80,重量26 と小型軽量で,遠位クランプがアーチ型のため自由な部位から1.6の遠位ピンを多数刺入できるという特徴がある.不安定型橈骨遠位端骨折に対する小型Non-bridge 型創外固定の治療成績を,従来の経皮的鋼線刺入固定の治療と比較検討した.両群ともに全例good 以上(斉藤による)の成績が得られたが,前者の方が低侵襲で早期より手関節が使えることから患者の満足度が高かった.", "subitem_description_type": "Abstract"}]}, "item_2_identifier_60": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "URI", "subitem_identifier_uri": "http://ir.cc.sapmed.ac.jp/dspace/handle/123456789/3487"}]}, "item_2_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "北海道整形外科外傷研究会"}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0914-6083", "subitem_source_identifier_type": "ISSN"}]}, "item_2_version_type_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "畑中, 渉"}], "nameIdentifiers": [{"nameIdentifier": "13725", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-07-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "n091460832410.pdf", "filesize": [{"value": "210.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 210300.0, "url": {"label": "n091460832410.pdf", "url": "https://sapmed.repo.nii.ac.jp/record/10513/files/n091460832410.pdf"}, "version_id": "424dc01b-35af-4a67-912c-31bec3ccc40e"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Distal radius fracture", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "External fixation", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Non-bridge type", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "橈骨遠位端骨折", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "創外固定", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "関節非架橋型", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "不安定型橈骨遠位端骨折に対するNon-bridge 型創外固定(Techno FIX)の治療成績", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "不安定型橈骨遠位端骨折に対するNon-bridge 型創外固定(Techno FIX)の治療成績", "subitem_title_language": "ja"}]}, "item_type_id": "2", "owner": "15", "path": ["1749"], "permalink_uri": "https://sapmed.repo.nii.ac.jp/records/10513", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2009-09-07"}, "publish_date": "2009-09-07", "publish_status": "0", "recid": "10513", "relation": {}, "relation_version_is_last": true, "title": ["不安定型橈骨遠位端骨折に対するNon-bridge 型創外固定(Techno FIX)の治療成績"], "weko_shared_id": -1}
不安定型橈骨遠位端骨折に対するNon-bridge 型創外固定(Techno FIX)の治療成績
https://sapmed.repo.nii.ac.jp/records/10513
https://sapmed.repo.nii.ac.jp/records/10513685ebada-0b7f-4aa1-af75-c234afda2c7f
名前 / ファイル | ライセンス | アクション |
---|---|---|
n091460832410.pdf (210.3 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-09-07 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 不安定型橈骨遠位端骨折に対するNon-bridge 型創外固定(Techno FIX)の治療成績 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Distal radius fracture | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | External fixation | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Non-bridge type | |||||
キーワード | ||||||
言語 | ja | |||||
主題Scheme | Other | |||||
主題 | 橈骨遠位端骨折 | |||||
キーワード | ||||||
言語 | ja | |||||
主題Scheme | Other | |||||
主題 | 創外固定 | |||||
キーワード | ||||||
言語 | ja | |||||
主題Scheme | Other | |||||
主題 | 関節非架橋型 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
畑中, 渉
× 畑中, 渉 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Non-bridge 型創外固定(Techno FIX)は全長80,重量26 と小型軽量で,遠位クランプがアーチ型のため自由な部位から1.6の遠位ピンを多数刺入できるという特徴がある.不安定型橈骨遠位端骨折に対する小型Non-bridge 型創外固定の治療成績を,従来の経皮的鋼線刺入固定の治療と比較検討した.両群ともに全例good 以上(斉藤による)の成績が得られたが,前者の方が低侵襲で早期より手関節が使えることから患者の満足度が高かった. | |||||
書誌情報 |
北海道整形外科外傷研究会会誌 = The Journal of Hokkaido Orthopaedic Traumatology Association 巻 24, p. 10-12, 発行日 2008-03-31 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0914-6083 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | 北海道整形外科外傷研究会 |